Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Eur J Neurol ; 30(8): 2206-2214, 2023 08.
Article in English | MEDLINE | ID: mdl-37151137

ABSTRACT

BACKGROUND AND PURPOSE: Automatic 3D video analysis of the lower body during rapid eye movement (REM) sleep has been recently proposed as a novel tool for identifying people with isolated REM sleep behavior disorder (iRBD), but, so far, it has not been validated on unseen subjects. This study aims at validating this technology in a large cohort and at improving its performances by also including an analysis of movements in the head, hands and upper body. METHODS: Fifty-three people with iRBD and 128 people without RBD (of whom 89 had sleep disorders considered RBD differential diagnoses) were included in the study. An automatic algorithm identified movements from 3D videos during REM sleep in four regions of interest (ROIs): head, hands, upper body and lower body. The movements were divided into categories according to duration: short (0.1-2 s), medium (2-15 s) and long (15-300 s). For each ROI and duration range, features were obtained from the identified movements. Logistic regression models using as predictors the features from one single ROI or a combination of ROIs were trained and tested in a 10-runs 10-fold cross-validation scheme on the task of differentiating people with iRBD from people without RBD. RESULTS: The best differentiation was achieved using short movements in all four ROIs (test accuracy 0.866 ± 0.007, test F1 score = 0.783 ± 0.010). Single group analyses showed that people with iRBD were distinguished successfully from subjects with RBD differential diagnoses. CONCLUSIONS: Automatic 3D video analysis might be implemented in clinical routine as a supportive screening tool for identifying people with RBD.


Subject(s)
REM Sleep Behavior Disorder , Humans , REM Sleep Behavior Disorder/diagnosis , Movement , Sleep, REM , Polysomnography
2.
Clin EEG Neurosci ; 54(3): 316-326, 2023 May.
Article in English | MEDLINE | ID: mdl-34658289

ABSTRACT

Background: Functional (un-)coupling (task-related change of functional connectivity) between different sites of the brain is a mechanism of general importance for cognitive processes. In Alzheimer's disease (AD), prior research identified diminished cortical connectivity as a hallmark of the disease. However, little is known about the relation between the amount of functional (un-)coupling and cognitive performance and decline in AD. Method: Cognitive performance (based on CERAD-Plus scores) and electroencephalogram (EEG)-based functional (un-)coupling measures (connectivity changes from rest to a Face-Name-Encoding task) were assessed in 135 AD patients (age: M = 73.8 years; SD = 9.0). Of these, 68 patients (M = 73.9 years; SD = 8.9) participated in a follow-up assessment of their cognitive performance 1.5 years later. Results: The amounts of functional (un-)coupling in left anterior-posterior and homotopic interhemispheric connections in beta1-band were related to cognitive performance at baseline (ß = .340; p < .001; ß = .274; P = .001, respectively). For both markers, a higher amount of functional coupling was associated with better cognitive performance. Both markers also were significant predictors for cognitive decline. However, while patients with greater functional coupling in left anterior-posterior connections declined less in cognitive performance (ß = .329; P = .035) those with greater functional coupling in interhemispheric connections declined more (ß = -.402; P = .010). Conclusion: These findings suggest an important role of functional coupling mechanisms in left anterior-posterior and interhemispheric connections in AD. Especially the complex relationship with cognitive decline in AD patients might be an interesting aspect for future studies.


Subject(s)
Alzheimer Disease , Cognitive Dysfunction , Humans , Aged , Magnetic Resonance Imaging , Electroencephalography/methods , Brain , Disease Progression
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4222-4225, 2022 07.
Article in English | MEDLINE | ID: mdl-36085969

ABSTRACT

Movements during sleep characterize sleep disorders, which can disturb sleep or its onset, impacting sleep quantity and quality. Video-polysomnography is the current gold standard to assess movements during sleep, but its availability is limited. Using data recorded with a 3D time of flight sensor, we developed a novel method of encoding temporal and spatial information of automatically identified movements during sleep. In a cohort of 20 insomnia patients and 18 controls, we showed that this novel method holds important information able to discriminate the groups. Future studies will explore the methodology in the context of other sleep disorders.


Subject(s)
Sleep Initiation and Maintenance Disorders , Sleep Wake Disorders , Humans , Movement , Polysomnography/methods , Sleep
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7050-7053, 2021 11.
Article in English | MEDLINE | ID: mdl-34892726

ABSTRACT

Rapid eye movement (REM) sleep behavior disorder (RBD) is a parasomnia characterized by dream enactment, abnormal jerks and movements during REM sleep. Isolated RBD (iRBD) is recognized as the early stage of alpha-synucleinopathies, i.e. dementia with Lewy bodies, Parkinson's disease and multiple system atrophy. The certain diagnosis of iRBD requires video-polysomnography, evaluated by experts with time-consuming visual analyses. In this study, we propose automatic analysis of movements detected with 3D contactless video as a promising technology to assist sleep experts in the identification of patients with iRBD. By using automatically detected upper and lower body movements occurring during REM sleep with a duration between 4s and 5s, we could discriminate 20 iRBD patients from 24 patients with sleep-disordered breathing with an accuracy of 0.91 and F1-score of 0.90. This pilot study shows that 3D contactless video can be successfully used as a non-invasive technology to assist clinicians in identifying abnormal movements during REM sleep, and therefore to recognize patients with iRBD. Future investigations in larger cohorts are needed to validate the proposed technology and methodology.


Subject(s)
Parkinson Disease , REM Sleep Behavior Disorder , Humans , Parkinson Disease/diagnosis , Pilot Projects , Polysomnography , REM Sleep Behavior Disorder/diagnosis , Sleep, REM
5.
Data Brief ; 35: 106770, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33553523

ABSTRACT

The cartoon Fidgety Philip, the banner of Western-ADHD diagnosis, depicts a 'restless' child exhibiting hyperactive-behaviors with hyper-arousability and/or hypermotor-restlessness (H-behaviors) during sitting. To overcome the gaps between differential diagnostic considerations and modern computing methodologies, we have developed a non-interpretative, neutral pictogram-guided phenotyping language (PG-PL) for describing body-segment movements during sitting (Journal of Psychiatric Research). To develop the PG-PL, seven research assistants annotated three original Fidgety Philip cartoons. Their annotations were analyzed with descriptive statistics. To review the PG-PL's performance, the same seven research assistants annotated 12 snapshots with free hand annotations, followed by using the PG-PL, each time in randomized sequence and on two separate occasions. After achieving satisfactory inter-observer agreements, the PG-PL annotation software was used for reviewing videos where the same seven research assistants annotated 12 one-minute long video clips. The video clip annotations were finally used to develop a machine learning algorithm for automated movement detection (Journal of Psychiatric Research). These data together demonstrate the value of the PG-PL for manually annotating human movement patterns. Researchers are able to reuse the data and the first version of the machine learning algorithm to further develop and refine the algorithm for differentiating movement patterns.

6.
IEEE J Biomed Health Inform ; 25(1): 181-188, 2021 01.
Article in English | MEDLINE | ID: mdl-32324578

ABSTRACT

OBJECTIVE: The purpose of this study was to derive a respiratory movement signal from a 3D time-of-flight camera and to investigate if it can be used in combination with SpO2 to detect respiratory events comparable to polysomnography (PSG) based detection. METHODS: We derived a respiratory signal from a 3D camera and developed a new algorithm that detects reduced respiratory movement and SpO2 desaturation to score respiratory events. The method was tested on 61 patients' synchronized 3D video and PSG recordings. The predicted apnea-hypopnea index (AHI), calculated based on total sleep time, and predicted severity were compared to manual PSG annotations (manualPSG). Predicted AHI evaluation, measured by intraclass correlation (ICC), and severity classification were performed. Furthermore, the results were evaluated by 30-second epoch analysis, labelled either as respiratory event or normal breathing, wherein the accuracy, sensitivity, specificity and Cohen's kappa were calculated. RESULTS: The predicted AHI scored an ICC r = 0.94 (0.90 - 0.96 at 95% confidence interval, p < 0.001) compared to manualPSG. Severity classification scored 80% accuracy, with no misclassification by more than one severity level. Based on 30-second epoch analysis, the method scored a Cohen's kappa = 0.72, accuracy = 0.88, sensitivity = 0.80, and specificity = 0.91. CONCLUSION: Our detection method using SpO2 and 3D camera had excellent reliability and substantial agreement with PSG-based scoring. SIGNIFICANCE: This method showed the potential to reliably detect respiratory events without airflow and respiratory belt sensors, sensors that can be uncomfortable to patients and susceptible to movement artefacts.


Subject(s)
Sleep Apnea, Obstructive , Humans , Oximetry , Oxygen , Polysomnography , Reproducibility of Results
7.
J Psychiatr Res ; 131: 144-151, 2020 12.
Article in English | MEDLINE | ID: mdl-32971358

ABSTRACT

BACKGROUND: Behavioral observations support clinical in-depth phenotyping but phenotyping and pattern recognition are affected by training background. As Attention Deficit Hyperactivity Disorder, Restless Legs syndrome/Willis Ekbom disease and medication induced activation syndromes (including increased irritability and/or akathisia), present with hyperactive-behaviors with hyper-arousability and/or hypermotor-restlessness (H-behaviors), we first developed a non-interpretative, neutral pictogram-guided phenotyping language (PG-PL) for describing body-segment movements during sitting. METHODOLOGY & RESULTS: The PG-PL was applied for annotating 12 1-min sitting-videos (inter-observer agreements >85%->97%) and these manual annotations were used as a ground truth to develop an automated algorithm using OpenPose, which locates skeletal landmarks in 2D video. We evaluated the algorithm's performance against the ground truth by computing the area under the receiver operator curve (>0.79 for the legs, arms, and feet, but 0.65 for the head). While our pixel displacement algorithm performed well for the legs, arms, and feet, it predicted head motion less well, indicating the need for further investigations. CONCLUSION: This first automated analysis algorithm allows to start the discussion about distinct phenotypical characteristics of H-behaviors during structured behavioral observations and may support differential diagnostic considerations via in-depth phenotyping of sitting behaviors and, in consequence, of better treatment concepts.


Subject(s)
Attention Deficit Disorder with Hyperactivity , Restless Legs Syndrome , Algorithms , Humans , Machine Learning , Movement
8.
Sleep ; 43(11)2020 11 12.
Article in English | MEDLINE | ID: mdl-32573731

ABSTRACT

STUDY OBJECTIVES: The differentiation of isolated rapid eye movement (REM) sleep behavior disorder (iRBD) or its prodromal phase (prodromal RBD) from other disorders with motor activity during sleep is critical for identifying α-synucleinopathy in an early stage. Currently, definite RBD diagnosis requires video polysomnography (vPSG). The aim of this study was to evaluate automated 3D video analysis of leg movements during REM sleep as objective diagnostic tool for iRBD. METHODS: A total of 122 participants (40 iRBD, 18 prodromal RBD, 64 participants with other disorders with motor activity during sleep) were recruited among patients undergoing vPSG at the Sleep Disorders Unit, Department of Neurology, Medical University of Innsbruck. 3D videos synchronous to vPSG were recorded. Lower limb movements rate, duration, extent, and intensity were computed using a newly developed software. RESULTS: The analyzed 3D movement features were significantly increased in subjects with iRBD compared to prodromal RBD and other disorders with motor activity during sleep. Minor leg jerks with a duration < 2 seconds discriminated with the highest accuracy (90.4%) iRBD from other motor activity during sleep. Automatic 3D analysis did not differentiate between prodromal RBD and other disorders with motor activity during sleep. CONCLUSIONS: Automated 3D video analysis of leg movements during REM sleep is a promising diagnostic tool for identifying subjects with iRBD in a sleep laboratory population and is able to distinguish iRBD from subjects with other motor activities during sleep. For future application as a screening, further studies should investigate usefulness of this tool when no information about sleep stages from vPSG is available and in the home environment.


Subject(s)
REM Sleep Behavior Disorder , Humans , Lower Extremity , Polysomnography , REM Sleep Behavior Disorder/diagnosis , Sleep Stages , Sleep, REM
9.
J Sleep Res ; 29(5): e12986, 2020 10.
Article in English | MEDLINE | ID: mdl-32017288

ABSTRACT

In clinical practice, the quality of polysomnographic recordings in children and patients with neurodegenerative diseases may be affected by sensor displacement and diminished total sleep time due to stress during the recording. In the present study, we investigated if contactless three-dimensional (3D) detection of periodic leg movements during sleep was comparable to polysomnography. We prospectively studied a sleep laboratory cohort from two Austrian sleep laboratories. Periodic leg movements during sleep were classified according to the standards of the World Association of Sleep Medicine and served as ground truth. Leg movements including respiratory-related events (A1) and excluding respiratory-related events (A2 and A3) were presented as A1, A2 and A3. Three-dimensional movement analysis was carried out using an algorithm developed by the Austrian Institute of Technology. Fifty-two patients (22 female, mean age 52.2 ± 15.1 years) were included. Periodic leg movement during sleep indexes were significantly higher with 3D detection compared to polysomnography (33.3 [8.1-97.2] vs. 30.7 [2.9-91.9]: +9.1%, p = .0055/27.8 [4.5-86.2] vs. 24.2 [0.00-88.7]: +8.2%, p = .0154/31.8 [8.1-89.5] vs. 29.6 [2.4-91.1]: +8.9%, p = .0129). Contactless automatic 3D analysis has the potential to detect restlessness mirrored by periodic leg movements during sleep reliably and may especially be suited for children and the elderly.


Subject(s)
Imaging, Three-Dimensional/methods , Polysomnography/methods , Restless Legs Syndrome/diagnosis , Adult , Algorithms , Female , Humans , Male , Middle Aged , Pilot Projects , Videotape Recording
10.
Front Psychiatry ; 10: 709, 2019.
Article in English | MEDLINE | ID: mdl-31681030

ABSTRACT

Background: Unlike other episodic sleep disorders in childhood, there are no agreed severity indices for rhythmic movement disorder. While movements can be characterized in detail by polysomnography, in our experience most children inhibit rhythmic movement during polysomnography. Actigraphy and home video allow assessment in the child's own environment, but both have limitations. Standard actigraphy analysis algorithms fail to differentiate rhythmic movements from other movements. Manual annotation of 2D video is time consuming. We aimed to develop a sensitive, reliable method to detect and quantify rhythmic movements using marker free and automatic 3D video analysis. Method: Patients with rhythmic movement disorder (n = 6, 4 male) between age 5 and 14 years (M: 9.0 years, SD: 4.2 years) spent three nights in the sleep laboratory as part of a feasibility study (https://clinicaltrials.gov/ct2/show/NCT03528096). 2D and 3D video data recorded during the adaptation and baseline nights were analyzed. One ceiling-mounted camera captured 3D depth images, while another recorded 2D video. We developed algorithms to analyze the characteristics of rhythmic movements and built a classifier to distinguish between rhythmic and non-rhythmic movements based on 3D video data alone. Data from 3D automated analysis were compared to manual 2D video annotations to assess algorithm performance. Novel indices were developed, specifically the rhythmic movement index, frequency index, and duration index, to better characterize severity of rhythmic movement disorder in children. Result: Automatic 3D video analysis demonstrated high levels of agreement with the manual approach indicated by a Cohen's kappa >0.9 and F1-score >0.9. We also demonstrated how rhythmic movement assessment can be improved using newly introduced indices illustrated with plots for ease of visualization. Conclusion: 3D video technology is widely available and can be readily integrated into sleep laboratory settings. Our automatic 3D video analysis algorithm yields reliable quantitative information about rhythmic movements, reducing the burden of manual scoring. Furthermore, we propose novel rhythmic movement disorder severity indices that offer a means to standardize measurement of this disorder in both clinical and research practice. The significance of the results is limited due to the nature of a feasibility study and its small number of samples. A larger follow up study is needed to confirm presented results.

12.
Brain Behav ; 9(1): e01197, 2019 01.
Article in English | MEDLINE | ID: mdl-30592179

ABSTRACT

INTRODUCTION: Magnetic resonance imaging (MRI) and electroencephalography (EEG) are a promising means to an objectified assessment of cognitive impairment in Alzheimer's disease (AD). Individually, however, these modalities tend to lack precision in both AD diagnosis and AD staging. A joint MRI-EEG approach that combines structural with functional information has the potential to overcome these limitations. MATERIALS AND METHODS: This cross-sectional study systematically investigated the link between MRI and EEG markers and the global cognitive status in early AD. We hypothesized that the joint modalities would identify cognitive deficits with higher accuracy than the individual modalities. In a cohort of 111 AD patients, we combined MRI measures of cortical thickness and regional brain volume with EEG measures of rhythmic activity, information processing and functional coupling in a generalized multiple regression model. Machine learning classification was used to evaluate the markers' utility in accurately separating the subjects according to their cognitive score. RESULTS: We found that joint measures of temporal volume, cortical thickness, and EEG slowing were well associated with the cognitive status and explained 38.2% of ifs variation. The inclusion of the covariates age, sex, and education considerably improved the model. The joint markers separated the subjects with an accuracy of 84.7%, which was considerably higher than by using individual modalities. CONCLUSIONS: These results suggest that including joint MRI-EEG markers may be beneficial in the diagnostic workup, thus allowing for adequate treatment. Further studies in larger populations, with a longitudinal design and validated against functional-metabolic imaging are warranted to confirm the results.


Subject(s)
Alzheimer Disease/diagnostic imaging , Cognition/physiology , Cognitive Dysfunction/diagnostic imaging , Neuroimaging/methods , Aged , Aged, 80 and over , Alzheimer Disease/pathology , Alzheimer Disease/physiopathology , Biomarkers , Cognitive Dysfunction/pathology , Cognitive Dysfunction/physiopathology , Cross-Sectional Studies , Disease , Electroencephalography , Female , Humans , Machine Learning , Magnetic Resonance Imaging , Male
13.
Article in English | MEDLINE | ID: mdl-30582941

ABSTRACT

BACKGROUND: So far, no cost-efficient, widely-used biomarkers have been established to facilitate the objectivization of Alzheimer's disease (AD) diagnosis and monitoring. Research suggests that event-related potentials (ERPs) reflect neurodegenerative processes in AD and might qualify as neurophysiological AD markers. OBJECTIVES: First, to examine which ERP component correlates the most with AD severity, as measured by the Mini-Mental State Examination (MMSE). Then, to analyze the temporal change of this component as AD progresses. METHODS: Sixty-three subjects (31 with possible, 32 with probable AD diagnosis) were recruited as part of the cohort study Prospective Dementia Registry Austria (PRODEM). For a maximum of 18 months patients revisited every 6 months for follow-up assessments. ERPs were elicited using an auditory oddball paradigm. P300 and N200 latency was determined with regard to target as well as difference wave ERPs, whereas P50 amplitude was measured from standard stimuli waveforms. RESULTS: P300 latency exhibited the strongest association with AD severity (e.g., r = -0.512, p < 0.01 at Pz for target stimuli in probable AD subjects). Further, there were significant Pearson correlations for N200 latency (e.g., r = -0.407, p = 0.026 at Cz for difference waves in probable AD subjects). P50 amplitude, as measured by different detection methods and at various scalp sites, did not significantly correlate with disease severity - neither in probable AD, possible AD, nor in both subgroups of patients combined. ERP markers for the group of possible AD patients did not show any significant correlations with MMSE scores. Post-hoc pairwise comparisons between baseline and 18-months follow-up assessment revealed significant P300 latency differences (e.g., p < 0.001 at Cz for difference waves in probable AD subjects). However, there were no significant correlations between the change rates of P300 latency and MMSE score. CONCLUSIONS: P300 and N200 latency significantly correlated with disease severity in probable AD, whereas P50 amplitude did not. P300 latency, which showed the highest correlation coefficients with MMSE, significantly increased over the course of the 18 months study period in probable AD patients. The magnitude of the observed prolongation is in line with other longitudinal AD studies and substantially higher than in normal ageing, as reported in previous trials (no healthy controls were included in our study).


Subject(s)
Alzheimer Disease/physiopathology , Brain/physiopathology , Evoked Potentials , Aged , Alzheimer Disease/diagnosis , Alzheimer Disease/genetics , Apolipoproteins E/genetics , Disease Progression , Electroencephalography , Evoked Potentials/physiology , Female , Follow-Up Studies , Humans , Longitudinal Studies , Male , Mental Status and Dementia Tests , Prospective Studies , Severity of Illness Index
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 6010-6013, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30441706

ABSTRACT

Electroencephalogram (EEG) is a common tool in sleep medicine, but it is often compromised by non-neural artifacts. Excluding visually identified artifacts is time-consuming and removes relevant EEG information. Blind source separation (BSS) techniques, on the other hand, are capable of separating "brain" from "artifact source components". Existing algorithms for automated component labeling require either a priori morphological information or adaptation to individual recordings. We present a method for the automated identification of artifact components based on their autocorrelation and spectral properties. It requires no tuning for individual recordings. The method was tested on 100 one-minute EEG segments during rapid eye movement sleep. EEG source components were estimated by second order blind source identification and, as reference, manually labeled as "brain" or "artifact component". The algorithm identified electro-cardiogram components by autocorrelation peaks between 0.5-1.5 seconds and -oculogram components by linear discriminant analysis of spectral band-power. Using 5-fold cross-validation, we observed 97% accuracy (95% sensitivity, 98% specificity), as well as minimized correlation of artifacts and the EEG. The approach has demonstrated its potential as promising tool for a broad range of sleep medical applications.


Subject(s)
Artifacts , Electroencephalography , Pattern Recognition, Automated , Signal Processing, Computer-Assisted , Sleep , Algorithms , Discriminant Analysis , Humans
15.
J Alzheimers Dis ; 62(1): 247-268, 2018.
Article in English | MEDLINE | ID: mdl-29439335

ABSTRACT

The present study tested the hypothesis that cortical sources of resting state eyes-closed electroencephalographic (rsEEG) rhythms reveal different abnormalities in cortical neural synchronization in groups of patients with mild cognitive impairment due to Alzheimer's disease (ADMCI) and dementia with Lewy bodies (DLBMCI) as compared to cognitively normal elderly (Nold) subjects. Clinical and rsEEG data in 30 ADMCI, 23 DLBMCI, and 30 Nold subjects were available in an international archive. Age, gender, and education were carefully matched in the three groups. The Mini-Mental State Evaluation (MMSE) score was matched between the ADMCI and DLBMCI groups. Individual alpha frequency peak (IAF) was used to determine the delta, theta, alpha1, alpha2, and alpha3 frequency band ranges. Fixed beta1, beta2, and gamma bands were also considered. eLORETA estimated the rsEEG cortical sources. Receiver operating characteristic curve (ROCC) classified these sources across individuals. Compared to Nold, IAF showed marked slowing in DLBMCI and moderate in ADMCI. Furthermore, the posterior alpha 2 and alpha 3 source activities were more abnormal in the ADMCI than the DLBMCI group, while widespread delta source activities were more abnormal in the DLBMCI than the ADMCI group. The posterior delta and alpha sources correlated with the MMSE score and correctly classified the Nold and MCI individuals (area under the ROCC >0.85). In conclusion, the ADMCI and DLBMCI patients showed different features of cortical neural synchronization at delta and alpha frequencies underpinning brain arousal and vigilance in the quiet wakefulness. Future prospective cross-validation studies will have to test the clinical validity of these rsEEG markers.


Subject(s)
Alzheimer Disease/physiopathology , Brain/physiopathology , Cognitive Dysfunction/physiopathology , Electroencephalography , Lewy Body Disease/physiopathology , Aged , Alzheimer Disease/complications , Alzheimer Disease/diagnosis , Alzheimer Disease/drug therapy , Brain/drug effects , Cognitive Dysfunction/diagnosis , Cognitive Dysfunction/drug therapy , Cognitive Dysfunction/etiology , Educational Status , Female , Humans , Lewy Body Disease/complications , Lewy Body Disease/diagnosis , Lewy Body Disease/drug therapy , Male , Psychotropic Drugs/therapeutic use , Rest , Retrospective Studies , Signal Processing, Computer-Assisted
16.
Clin Neurophysiol ; 129(4): 766-782, 2018 04.
Article in English | MEDLINE | ID: mdl-29448151

ABSTRACT

OBJECTIVE: This study tested the hypothesis that markers of functional cortical source connectivity of resting state eyes-closed electroencephalographic (rsEEG) rhythms may be abnormal in subjects with mild cognitive impairment due to Alzheimer's (ADMCI) and Parkinson's (PDMCI) diseases compared to healthy elderly subjects (Nold). METHODS: rsEEG data had been collected in ADMCI, PDMCI, and Nold subjects (N = 75 for any group). eLORETA freeware estimated functional lagged linear connectivity (LLC) from rsEEG cortical sources. Area under receiver operating characteristic (AUROC) curve indexed the accuracy in the classification of Nold and MCI individuals. RESULTS: Posterior interhemispheric and widespread intrahemispheric alpha LLC solutions were abnormally lower in both MCI groups compared to the Nold group. At the individual level, AUROC curves of LLC solutions in posterior alpha sources exhibited moderate accuracies (0.70-0.72) in the discrimination of Nold vs. ADMCI-PDMCI individuals. No differences in the LLC solutions were found between the two MCI groups. CONCLUSIONS: These findings unveil similar abnormalities in functional cortical connectivity estimated in widespread alpha sources in ADMCI and PDMCI. This was true at both group and individual levels. SIGNIFICANCE: The similar abnormality of alpha source connectivity in ADMCI and PDMCI subjects might reflect common cholinergic impairment.


Subject(s)
Alpha Rhythm/physiology , Alzheimer Disease/physiopathology , Cerebral Cortex/physiology , Cognitive Dysfunction/physiopathology , Electroencephalography/methods , Parkinson Disease/physiopathology , Aged , Alzheimer Disease/diagnosis , Alzheimer Disease/psychology , Cognitive Dysfunction/diagnosis , Cognitive Dysfunction/psychology , Female , Humans , Male , Neuropsychological Tests , Parkinson Disease/diagnosis , Parkinson Disease/psychology , Rest/physiology , Retrospective Studies
17.
Neurobiol Aging ; 65: 18-40, 2018 05.
Article in English | MEDLINE | ID: mdl-29407464

ABSTRACT

Previous evidence showed abnormal posterior sources of resting-state delta (<4 Hz) and alpha (8-12 Hz) rhythms in patients with Alzheimer's disease with dementia (ADD), Parkinson's disease with dementia (PDD), and Lewy body dementia (DLB), as cortical neural synchronization markers in quiet wakefulness. Here, we tested the hypothesis of additional abnormalities in functional cortical connectivity computed in those sources, in ADD, considered as a "disconnection cortical syndrome", in comparison with PDD and DLB. Resting-state eyes-closed electroencephalographic (rsEEG) rhythms had been collected in 42 ADD, 42 PDD, 34 DLB, and 40 normal healthy older (Nold) participants. Exact low-resolution brain electromagnetic tomography (eLORETA) freeware estimated the functional lagged linear connectivity (LLC) from rsEEG cortical sources in delta, theta, alpha, beta, and gamma bands. The area under receiver operating characteristic (AUROC) curve indexed the classification accuracy between Nold and diseased individuals (only values >0.7 were considered). Interhemispheric and intrahemispheric LLCs in widespread delta sources were abnormally higher in the ADD group and, unexpectedly, normal in DLB and PDD groups. Intrahemispheric LLC was reduced in widespread alpha sources dramatically in ADD, markedly in DLB, and moderately in PDD group. Furthermore, the interhemispheric LLC in widespread alpha sources showed lower values in ADD and DLB than PDD groups. At the individual level, AUROC curves of LLC in alpha sources exhibited better classification accuracies for the discrimination of ADD versus Nold individuals (0.84) than for DLB versus Nold participants (0.78) and PDD versus Nold participants (0.75). Functional cortical connectivity markers in delta and alpha sources suggest a more compromised neurophysiological reserve in ADD than DLB, at both group and individual levels.


Subject(s)
Alzheimer Disease/complications , Cerebral Cortex/physiology , Cognition/physiology , Dementia/etiology , Dementia/psychology , Electroencephalography , Lewy Body Disease/complications , Rest/physiology , Aged , Cerebral Cortex/diagnostic imaging , Cortical Synchronization/physiology , Dementia/diagnosis , Dementia/physiopathology , Female , Humans , Male
18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 3793-3796, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060724

ABSTRACT

Electroencephalogram (EEG) signal quality is often compromised by artifacts that corrupt quantitative EEG measurements used in clinical applications and EEG-related studies. Techniques such as filtering, regression analysis and blind source separation are often used to remove these artifacts. However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic artifact set. Five EEG features were used to quantify temporal and spatial signal variations. Two distance measures for the single-channel and multi-channel variations of these features were defined. The global thresholds were determined by three-fold cross-validation and Youden's J statistic in conjunction with receiver operating characteristics (ROC curves). We observed high sensitivity of 95.5%±4.8 and specificity of 88.8%±2.1. The method has thus shown great potential and is promising as a possible tool for both EEG-based clinical applications and EEG-related research.


Subject(s)
Electroencephalography , Algorithms , Artifacts , Signal Processing, Computer-Assisted
19.
J Alzheimers Dis ; 59(1): 339-358, 2017.
Article in English | MEDLINE | ID: mdl-28621693

ABSTRACT

The aim of this retrospective and exploratory study was that the cortical sources of resting state eyes-closed electroencephalographic (rsEEG) rhythms might reveal different abnormalities in cortical neural synchronization in groups of patients with mild cognitive impairment due to Alzheimer's disease (ADMCI) and Parkinson's disease (PDMCI) as compared to healthy subjects. Clinical and rsEEG data of 75 ADMCI, 75 PDMCI, and 75 cognitively normal elderly (Nold) subjects were available in an international archive. Age, gender, and education were carefully matched in the three groups. The Mini-Mental State Evaluation (MMSE) was matched between the ADMCI and PDMCI groups. Individual alpha frequency peak (IAF) was used to determine the delta, theta, alpha1, alpha2, and alpha3 frequency band ranges. Fixed beta1, beta2, and gamma bands were also considered. eLORETA estimated the rsEEG cortical sources. Receiver operating characteristic curve (ROC) classified these sources across individuals. Results showed that compared to the Nold group, the posterior alpha2 and alpha3 source activities were more abnormal in the ADMCI than the PDMCI group, while the parietal delta source activities were more abnormal in the PDMCI than the ADMCI group. The parietal delta and alpha sources correlated with MMSE score and correctly classified the Nold and diseased individuals (area under the ROC = 0.77-0.79). In conclusion, the PDMCI and ADMCI patients showed different features of cortical neural synchronization at delta and alpha frequencies underpinning brain arousal and vigilance in the quiet wakefulness. Future prospective cross-validation studies will have to test these rsEEG markers for clinical applications and drug discovery.


Subject(s)
Alzheimer Disease/complications , Brain Waves/physiology , Cerebral Cortex/physiopathology , Cognitive Dysfunction/etiology , Cognitive Dysfunction/pathology , Parkinson Disease/complications , Aged , Aged, 80 and over , Electroencephalography , Female , Humans , Male , Mental Status Schedule , Middle Aged , Neuropsychological Tests , Retrospective Studies , Spectrum Analysis
20.
Neurobiol Aging ; 55: 143-158, 2017 07.
Article in English | MEDLINE | ID: mdl-28454845

ABSTRACT

The aim of this retrospective exploratory study was that resting state eyes-closed electroencephalographic (rsEEG) rhythms might reflect brain arousal in patients with dementia due to Alzheimer's disease dementia (ADD), Parkinson's disease dementia (PDD), and dementia with Lewy body (DLB). Clinical and rsEEG data of 42 ADD, 42 PDD, 34 DLB, and 40 healthy elderly (Nold) subjects were available in an international archive. Demography, education, and Mini-Mental State Evaluation score were not different between the patient groups. Individual alpha frequency peak (IAF) determined the delta, theta, alpha 1, alpha 2, and alpha 3 frequency bands. Fixed beta 1, beta 2, and gamma bands were also considered. rsEEG cortical sources were estimated by means of the exact low-resolution brain electromagnetic source tomography and were then classified across individuals, on the basis of the receiver operating characteristic curves. Compared to Nold, IAF showed marked slowing in PDD and DLB and moderate slowing in ADD. Furthermore, all patient groups showed lower posterior alpha 2 source activities. This effect was dramatic in ADD, marked in DLB, and moderate in PDD. These groups also showed higher occipital delta source activities, but this effect was dramatic in PDD, marked in DLB, and moderate in ADD. The posterior delta and alpha sources allowed good classification accuracy (approximately 0.85-0.90) between the Nold subjects and patients, and between ADD and PDD patients. In quiet wakefulness, delta and alpha sources unveiled different spatial and frequency features of the cortical neural synchronization underpinning brain arousal in ADD, PDD, and DLB patients. Future prospective cross-validation studies should test these rsEEG markers for clinical applications and drug discovery.


Subject(s)
Alzheimer Disease/physiopathology , Cerebral Cortex/physiopathology , Cortical Synchronization/physiology , Electroencephalography , Lewy Body Disease/physiopathology , Aged , Female , Humans , Male , Ocular Physiological Phenomena , Rest/physiology , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...